RDP-60 – Portable Chilled Mirror Hygrometer
Field moisture verification and industrial gas measurement
Key Features
Chilled mirror dew point measurement technology
High measurement accuracy and stability
Fast stabilization and reliable results
Designed for industrial and laboratory environments
Measurement Specifications
Measurement principle
Chilled mirror dew point
Measurement range
Model dependent
Accuracy
±0.2 °C
Resolution
0.01 °C
Repeatability
±0.05 °C
Typical response time
<5 minutes
Applications
Calibration laboratories
Industrial gas systems
Power utilities
Research laboratories
Ordering Information
Model: RDP-60
Optional accessories: pressure regulator, sample conditioning system, calibration service
RDP-70 – Laboratory Chilled Mirror Hygrometer
Reference-grade hygrometer for calibration laboratories
Key Features
Chilled mirror dew point measurement technology
High measurement accuracy and stability
Fast stabilization and reliable results
Designed for industrial and laboratory environments
Measurement Specifications
Measurement principle
Chilled mirror dew point
Measurement range
Model dependent
Accuracy
±0.2 °C
Resolution
0.01 °C
Repeatability
±0.05 °C
Typical response time
<5 minutes
Applications
Calibration laboratories
Industrial gas systems
Power utilities
Research laboratories
Ordering Information
Model: RDP-70
Optional accessories: pressure regulator, sample conditioning system, calibration service
RDP-80 – Extended Range Laboratory Hygrometer
Ultra‑low frost point measurement for advanced labs
Key Features
Chilled mirror dew point measurement technology
High measurement accuracy and stability
Fast stabilization and reliable results
Designed for industrial and laboratory environments
Measurement Specifications
Measurement principle
Chilled mirror dew point
Measurement range
Model dependent
Accuracy
±0.2 °C
Resolution
0.01 °C
Repeatability
±0.05 °C
Typical response time
<5 minutes
Applications
Calibration laboratories
Industrial gas systems
Power utilities
Research laboratories
Ordering Information
Model: RDP-80
Optional accessories: pressure regulator, sample conditioning system, calibration service
RDP-206 – SF6 Precision Dew Point Hygrometer
Moisture measurement for SF6 gas systems and GIS equipment
Key Features
Chilled mirror dew point measurement technology
High measurement accuracy and stability
Fast stabilization and reliable results
Designed for industrial and laboratory environments
Measurement Specifications
Measurement principle
Chilled mirror dew point
Measurement range
Model dependent
Accuracy
±0.2 °C
Resolution
0.01 °C
Repeatability
±0.05 °C
Typical response time
<5 minutes
Applications
Calibration laboratories
Industrial gas systems
Power utilities
Research laboratories
Ordering Information
Model: RDP-206
Optional accessories: pressure regulator, sample conditioning system, calibration service