RDP-60 – Portable Chilled Mirror Hygrometer

Field moisture verification and industrial gas measurement

Key Features

Chilled mirror dew point measurement technology

High measurement accuracy and stability

Fast stabilization and reliable results

Designed for industrial and laboratory environments

Measurement Specifications

Measurement principle

Chilled mirror dew point

Measurement range

Model dependent

Accuracy

±0.2 °C

Resolution

0.01 °C

Repeatability

±0.05 °C

Typical response time

<5 minutes

Applications

Calibration laboratories

Industrial gas systems

Power utilities

Research laboratories

Ordering Information

Model: RDP-60

Optional accessories: pressure regulator, sample conditioning system, calibration service

RDP-70 – Laboratory Chilled Mirror Hygrometer

Reference-grade hygrometer for calibration laboratories

Key Features

Chilled mirror dew point measurement technology

High measurement accuracy and stability

Fast stabilization and reliable results

Designed for industrial and laboratory environments

Measurement Specifications

Measurement principle

Chilled mirror dew point

Measurement range

Model dependent

Accuracy

±0.2 °C

Resolution

0.01 °C

Repeatability

±0.05 °C

Typical response time

<5 minutes

Applications

Calibration laboratories

Industrial gas systems

Power utilities

Research laboratories

Ordering Information

Model: RDP-70

Optional accessories: pressure regulator, sample conditioning system, calibration service

RDP-80 – Extended Range Laboratory Hygrometer

Ultra‑low frost point measurement for advanced labs

Key Features

Chilled mirror dew point measurement technology

High measurement accuracy and stability

Fast stabilization and reliable results

Designed for industrial and laboratory environments

Measurement Specifications

Measurement principle

Chilled mirror dew point

Measurement range

Model dependent

Accuracy

±0.2 °C

Resolution

0.01 °C

Repeatability

±0.05 °C

Typical response time

<5 minutes

Applications

Calibration laboratories

Industrial gas systems

Power utilities

Research laboratories

Ordering Information

Model: RDP-80

Optional accessories: pressure regulator, sample conditioning system, calibration service

RDP-206 – SF6 Precision Dew Point Hygrometer

Moisture measurement for SF6 gas systems and GIS equipment

Key Features

Chilled mirror dew point measurement technology

High measurement accuracy and stability

Fast stabilization and reliable results

Designed for industrial and laboratory environments

Measurement Specifications

Measurement principle

Chilled mirror dew point

Measurement range

Model dependent

Accuracy

±0.2 °C

Resolution

0.01 °C

Repeatability

±0.05 °C

Typical response time

<5 minutes

Applications

Calibration laboratories

Industrial gas systems

Power utilities

Research laboratories

Ordering Information

Model: RDP-206

Optional accessories: pressure regulator, sample conditioning system, calibration service